EXAIR Starter Guide: Line Vacs
So you just bought an EXAIR Line Vac... Now what?
EXAIR's latest series of videos will focus on some tips and tricks to help you get started with your EXAIR product.
Watch this video on some things to consider when getting started with your new Super Air Knife.
#manufacturing #engineering #compressedair #cnc #machining #airknife
Переглядів: 22

Відео

EXAIR Starter Guide: Cabinet Cooler Systems
Переглядів 123Місяць тому
EXAIR Starter Guide: Cabinet Cooler Systems
EXAIR Starter Guide: Super Air Knives
Переглядів 1882 місяці тому
So you just bought an Air Knife... Now what? EXAIR's latest series of videos will focus on some tips and tricks to help you get started with your EXAIR product. Watch this video on some things to consider when getting started with your new Super Air Knife. #manufacturing #engineering #compressedair #cnc #machining #airknife
Varistat Benchtop Ionizer Unboxing
Переглядів 995 місяців тому
EXAIR's Varistat Benchtop Ionizer is the first EXAIR Static Eliminator that doesnt require compressed air to operate! Providing a constant and widespread stream of ionizing air, it's a great solution for hands-free and remote mounting static elimination. Watch a quick #unboxing video on what comes with the new Varistat Benchtop Ionizer. #static #staticelimination #compresedair #EXAIR #manufactu...
EXAIR's Varistat Benchtop Ionizer
Переглядів 5835 місяців тому
EXAIR's Varistat Benchtop Ionizer is our first blower-type static eliminator. Requiring no compressed air, the Varistat provides a constant and widespread stream of ionizing airflow to remove static in industrial processes. Watch this quick video and learn more about the Varistat. #static #staticelimination #engineering #manufacturing
Webinar: Compressed Air System Management Spring
Переглядів 516 місяців тому
In this webinar, learn how to optimize your compressed air system with secondary storage and understand its benefits. We'll also discuss how to manage system changes, and calculate tank sizes to best fit your facility. #engineering #compressedair #manufacturing
Webinar: SCFM, ACFM, ICFM, CFM... Why So Many Airfllows?
Переглядів 4276 місяців тому
There are a number of ways to measure air, but what do they all mean? Learn the differences between Air Flow terms used with compressed air equipment and gain a better understanding of how conditions impact the airflow with your compressed air equipment in this webinar. #manufacturing #airflow #compressedair #scfm #acfm #icfm #cfm
Webinar: Optimize Your Compressed Air Use By Turning It Off
Переглядів 266 місяців тому
Compressed air can be an expensive utility especially when not used efficiently. In this webinar, learn different tips and tricks for conserving compressed air usage in your facility. #manufacturing #compressedair #efficiency
Webinar: Break The Cycle of Replacing Electric Shop Vacuums
Переглядів 1816 місяців тому
EXAIR's Industrial Vacuums are completely pneumatic meaning they run solely on compressed air. In this webinar, learn some of the major benefits for your facility when you switch to pneumatic vacuums for your rugged industrial processes.
Webinar: Five Important Factors When Selecting Atomizing Spray Nozzles
Переглядів 1886 місяців тому
EXAIR carries a wide variety of Atomizing Nozzles for applications involving washing, rinsing, cooling, coating and more. In this webinar, learn some important factors to consider when choosing the right nozzle for your process. #compresedair #spraynozzle #manufacturing #atomization #rinsing #washing #cooling
Webinar: Compressed Air Safety and NIOSH Hierarchy of Controls
Переглядів 236 місяців тому
The NIOSH Hierarchy of Controls is a system set in place to help facilities make sure they are following all the necessary steps to keep employees safe. In this webinar, gain insights on how EXAIR products can help boost safety in your facility. #safety #safetyfirst #OSHA #manufacturing #compressedair
Use This Not That- Four Common Ways to Save Compressed Air in Your Plant
Переглядів 346 місяців тому
Use This Not That- Four Common Ways to Save Compressed Air in Your Plant
Understanding Static Electricity Webinar
Переглядів 626 місяців тому
Static buildup can become a major problem for manufacturing problems causing damage to products and processes as well as causing harmful shocks to employees. In this Webinar, learn the basics of static electricity and EXAIR products that help you combat it. #engineering #manufacturing #staticelectricity #compressedair
Beat the Heat! Compare the Options to Cool Your Hot Electrical Cabinets
Переглядів 276 місяців тому
Overheating electric panels can lead to costly shutdowns or disruptions to your processes. In this Webinar, we discuss some of the common ways that people cool their enclosures, and how they compare to EXAIR Cabinet Coolers. #manufacturing #compressedair #overheating #cabinetcooler
Intelligent Compressed Air Solutions for OSHA Compliance
Переглядів 236 місяців тому
EXAIR products are engineered with the safety of it's users in mind. Every EXAIR product not only will help with efficiency, but meets all OSHA standards for compliance. In this webinar, learn how switching to EXAIR products can help your facility reach all OSHA standards. #compressedair #safety #OSHA #manufacturing
Optimize Your Compressed Air in 6 Simple Steps
Переглядів 456 місяців тому
Optimize Your Compressed Air in 6 Simple Steps
Meet EXAIR's Team: Al Wooffitt
Переглядів 176 місяців тому
Meet EXAIR's Team: Al Wooffitt
The Importance of Pressure Gauges
Переглядів 186 місяців тому
The Importance of Pressure Gauges
How the EXAIR Gen4 Super Ion Air Knife Removes Static
Переглядів 1988 місяців тому
How the EXAIR Gen4 Super Ion Air Knife Removes Static
Unboxing of the EXAIR EasySwitch Wet-Dry Vac
Переглядів 969 місяців тому
Unboxing of the EXAIR EasySwitch Wet-Dry Vac
Unboxing of EXAIR's Mini Chip Vac and Mini Drum Vac
Переглядів 759 місяців тому
Unboxing of EXAIR's Mini Chip Vac and Mini Drum Vac
Unboxing of the EXAIR Vac-u-Gun
Переглядів 459 місяців тому
Unboxing of the EXAIR Vac-u-Gun
Unboxing of the EXAIR Chip Trapper System
Переглядів 1339 місяців тому
Unboxing of the EXAIR Chip Trapper System
Unboxing of the EXAIR Chip Vac, Heavy Duty Dry Vac & HEPA Dry Vac Systems
Переглядів 549 місяців тому
Unboxing of the EXAIR Chip Vac, Heavy Duty Dry Vac & HEPA Dry Vac Systems
Unboxing of the EXAIR Reversible, and High Lift Reversible Drum Vac
Переглядів 1119 місяців тому
Unboxing of the EXAIR Reversible, and High Lift Reversible Drum Vac
Unboxing and Overview of EXAIR Industrial Housekeeping Vacuums
Переглядів 599 місяців тому
Unboxing and Overview of EXAIR Industrial Housekeeping Vacuums
Introduction to EXAIR's ATEX Cabinet Coolers
Переглядів 1139 місяців тому
Introduction to EXAIR's ATEX Cabinet Coolers
How to Reset an EXAIR Cabinet Cooler System Thermostat
Переглядів 13911 місяців тому
How to Reset an EXAIR Cabinet Cooler System Thermostat
Tools of The Trade: How to use a Rotameter
Переглядів 149Рік тому
Tools of The Trade: How to use a Rotameter
EXAIR Cabinet Cooler® Systems Overview
Переглядів 1,6 тис.Рік тому
EXAIR Cabinet Cooler® Systems Overview

КОМЕНТАРІ

  • @GorVala
    @GorVala 4 роки тому

    Thank you for the video. Informative to the point. Two thumbs up

    • @exaircorporation
      @exaircorporation 4 роки тому

      Thank you for the request @Devdatta Yadav. We will add that to our lists for topics to cover. If you would like help sizing a receiver tank quicker, please contact an Application Engineer at Techelp@EXAIR.com or 1-800-903-9247.

  • @devdattayadav4022
    @devdattayadav4022 4 роки тому

    Pls make video .design of air recevier with calculation

  • @adriansosa1430
    @adriansosa1430 4 роки тому

    Thank you for your help! Could you tell me how to muffle a Yamaha generator

    • @exaircorporation
      @exaircorporation 4 роки тому

      @Adrian Sosa, thanks for the comment. The mufflers showcased within this video are all designed for use on compressed air. To reduce the sound level of a Yamaha generator you may want to reach out to the manufacturer to ensure the stock muffler is operating correctly. Sorry we cannot be of more help on this. Good luck in the search.

  • @bkad8281
    @bkad8281 4 роки тому

    how to exhaust the compressed air which is very high pressure and high air flow which is going into the material receiver with material like storage silos, reactors,hoppers and tanks............

    • @exaircorporation
      @exaircorporation 4 роки тому

      @Bharat Kadam - Thank you for the great question. There are several methods to help exhaust the motive air from the product. The two most popular solutions are: 1 - Use a cyclonic separator on the discharge of the Line Vac to help the materials drop out of the high velocity air stream and into the container. 2 - Reduce the operating pressure and try to let gravity help with the conveyance as much as possible. This will reduce the volumetric flow of air within the hose. There are several other options, if you would like to discuss them please reach out to us. Techelp@EXAIR.com or 1-800-903-9247 / +1-513-671-3322

  • @armandomendoza3167
    @armandomendoza3167 4 роки тому

    Silly question. Is the diaphragm gasoline resistant?

    • @exaircorporation
      @exaircorporation 4 роки тому

      @Armando Mendoza - Thank you for the question. These regulators are designed and manufactured for use with compressed air or other innert gases. These are not designed to be used with a liquid fuel. You may want to try searching for a fuel pressure regulator. Please let us know if we can help with any compressed air application!

  • @kevindick1110
    @kevindick1110 5 років тому

    Good Job, Kirk.

  • @telugubanker9769
    @telugubanker9769 5 років тому

    how to convert scfm to kg/min of air

    • @exaircorporation
      @exaircorporation 5 років тому

      @Hk technology it in telugu: Thanks for the comment! The question of converting SCFM to kg/min of air is not a common question. There is a conversion factor but some assumptions must be made to reach this conversion factor that is shown below. First though, kg/min would normally be a mass flow rate that is used in a larger duct where the air is under minimal pressure, think an intake on an automobile or a large air intake on a duct of a furnace. SCFM is generally used to give a “standard” list of variables that have been used to relate to a volumetric flow of a compressed gas that is being used within a process. So we normally would not use kg/min in our values for our products. If you still want to convert, 1 SCF x 0.0807 lbm x 0.4536 kg = 0.0366 kg/min min 1 SCF 1 lbm This is assuming 70°F air temperature at 14.7 psia. If you would like to discuss further, please contact an Application Engineer at 1-800-903-9247 or Techelp@EXAIR.com Thanks again!

    • @telugubanker9769
      @telugubanker9769 5 років тому

      @@exaircorporation thank u

  • @avnishdubey3739
    @avnishdubey3739 5 років тому

    What is the total cost of all the components

    • @exaircorporation
      @exaircorporation 5 років тому

      Hi Avnish! Model #3930, Medium Vortex Tube Cooling Kit, is currently $409 for all of the included components.

  • @koaungmyat3989
    @koaungmyat3989 5 років тому

    Not it sales in Myanmar's

    • @exaircorporation
      @exaircorporation 5 років тому

      Thank you for your contact. If you have any questions about EXAIR products, how to use them or how to buy them, please contact our International Sales Department at tylerdaniel@exair.com We will be glad to try and help.

  • @advancetech8996
    @advancetech8996 5 років тому

    I love your content. Thank you. www.advancetech.co.in/categories/esd-and-clean-room/ion-bars

  • @bashkillszombies
    @bashkillszombies 5 років тому

    I see these things selling for anywhere up to a grand on ebay, yet they're literally a twenty dollar 'vortex tube', nothing more. D:

    • @exaircorporation
      @exaircorporation 5 років тому

      @baspr0mpt - Thank you for the comment. The most accurate pricing for our Cabinet Cooler Systems is easily found directly on our site at www.EXAIR.com. There are several factors that go into our Cabinet Cooler Systems that do not show up in a bench-made vortex tube. While these do operate off the same physics principle as a vortex tube they are engineered and designed to be an efficient use of compressed air, maintain NEMA integrity of the electrical enclosure, and be easy to install. On top of those factors our systems have all been tested to UL and CE standard to ensure these meet their standards for commercial and industrial equipment. As far as the topic of this video is concerned the panel was rated for a NEMA type 4, 4X environment, a standard vortex tube mounted to this panel would not permit the panel to retain the NEMA rating. A simple vortex tube would not distribute the cold air throughout the panel to provide even cooling like a Cabinet Cooler with our cold air distribution kit offers. Additionally, a vent would need to be installed to permit flow out of the panel but not in. This would have to be sized correctly as to not apply any backpressure onto the cold outlet of the vortex tube that goes above 3 psig as that would affect the cooling produced by the tube. All EXAIR Cabinet Cooler Systems are designed to exhaust the same volumetric flow of air they are putting into the cabinet while maintaining optimal performance for the vortex principle. In addition, the thermostat control and cold air distribution kit ensure you are only utilizing compressed air when the panel needs to be cooled and that the interior of the panel is evenly cooled throughout rather than one central point. If you would like to discuss our Cabinet Cooler Systems or vortex tubes further our Application Engineers will gladly walk through your applications. Feel free to give us a call at 1-800-903-9247.

  • @rides8087
    @rides8087 5 років тому

    Nice job !!

  • @NoOneYT
    @NoOneYT 5 років тому

    A compressor with 20 SCFM is enough to use as a vaccum cleaner?

    • @exaircorporation
      @exaircorporation 5 років тому

      The Vac U Gun only requires 13 SCFM at 80 psig inlet pressure to achieve optimal performance. A 20 SCFM compressor would be plenty as long as it is outputting 20 SCFM at 80 psig. You aren't directly using the compressed as a vacuum cleaner. Depending on the application one of our other Industrial Housekeeping Products may fit better than the Vac U Gun. If you would like to discuss your application please feel free to reach out to our Application Engineers directly at Techelp@EXAIR.com or 1-800-903-9247. Thanks for the comment!

  • @marsmarin8
    @marsmarin8 5 років тому

    Por favor, qué potencia tiene el compresor de aire usado en el vídeo? Necesito comprar todo el sistema: Line Vac de 2", y compresor de aire para transportar pellet de madera a 7 metros de altura. Please, the power, the air compressor used in the video? I need to buy this system. Line Vac 2" and air compressor to transport wood pellet to 7 meters high. Thank You very much.

    • @exaircorporation
      @exaircorporation 5 років тому

      @Marsmarin8 , Thank you for the inquiry. The 2" Standard Line Vac will consume 45 SCFM of compressed air when powered at 80 psig inlet pressure. If you would like to discuss your application with us please reach out to Techelp@EXAIR.com and we will respond quickly to help you determine what may work.

  • @Jeremy-su3xy
    @Jeremy-su3xy 5 років тому

    Can it be used for the underground water leak detection?

    • @exaircorporation
      @exaircorporation 5 років тому

      @Jeremy, the Ultrasonic Leak Detector would not be able to sense through the ground. There are other types of tests and detectors used for underground water leaks. This detector would be a line of sight type meter. If you have other applications please feel free to reach out to us through e mail, phone, or chat. 1-800-903-9247 Techelp@EXAIR.com www.EXAIR.com

  • @THELIQUIDORANGE
    @THELIQUIDORANGE 5 років тому

    do you have a video with that nozzle and smoke o steam water to watch the flow????

    • @exaircorporation
      @exaircorporation 5 років тому

      While we do not have a smoke or steam test we do offer air pattern diagrams. That is a great suggestion. Keep an eye out in the event it comes through! Check out, www.exair.com/index.php/catalog/product/view/id/3893#divID , for the airflow pattern.

  • @javierugalde7679
    @javierugalde7679 6 років тому

    Good device for industry electrical cabinets

  • @hkellam9
    @hkellam9 6 років тому

    My 4 year old watched this video on his tablet and told me that this is the kind of vacuum he wants to have in his house haha! And he made me watch the whole video haha 😂

  • @Azntoo60
    @Azntoo60 6 років тому

    Thanks for video. Nowonder my air compressor has leaks

  • @firatyildirim2288
    @firatyildirim2288 6 років тому

    Cool

  • @williammolchan3883
    @williammolchan3883 6 років тому

    I need 2 1/2 or bigger . For my project I'm working on

    • @exaircorporation
      @exaircorporation 6 років тому

      What kind of material will you be passing through the Line Vac? If you would like to discuss this further, please feel free to contact us through chat, e-mail, or phone. www.exair.com/index.php/contact-us

  • @williammolchan3883
    @williammolchan3883 6 років тому

    Do you have any demo or slightly imperfect ones for sale I'm a gold miner on a budget .

    • @exaircorporation
      @exaircorporation 6 років тому

      Thanks for your inquiry William. We appreciate your interest in our Line Vac products and would like to point you to our 30 day guarantee for customers within the USA and Canada. I would not want to sell an imperfect product for a process and so we do honor a 30 day guarantee on stock products which is applicable to the Line Vac and accessories that are included in the Line Vac Kits. The only item that could not be returned to us for credit would be the conveyance hose.

  • @luizantoniosivieri539
    @luizantoniosivieri539 7 років тому

    Estou desenvolvendo um projeto e vou comprar seu produto,mas gostaria de saber para atender a vazão de 58,50 SCFM para tipo Line Vac 6065/6085 qual a capacidade do compressor e (reservatório se precisar) para fazer transporte de pimenta do reino. Obrigado

    • @exaircorporation
      @exaircorporation 6 років тому

      Obrigado por nos contactar Luiz, peço desculpa pelo atraso em resposta. Precisamos saber mais algumas informações sobre seu processo para garantir que o modelo 6065/6085 seja um bom ajuste. Se puder, entre em contato com um engenheiro de aplicativos aqui. Ligue ou envie um e-mail, 1-800-903-9247 ou techelp@exair.com Mais uma vez, Luiz!

  • @luizantoniosivieri539
    @luizantoniosivieri539 7 років тому

    Estou desenvolvendo um projeto e vou comprar seu produto,mas gostaria de saber para atender a vazão de 58,50 SCFM para tipo Line Vac 6065/6085 qual a capacidade do compressor e (reservatório se precisar) para fazer transporte de pimenta do reino. Obrigado

    • @exaircorporation
      @exaircorporation 7 років тому

      Luiz, Obrigado pela pergunta. Gostaria de discutir o aplicativo com você ainda antes de dar a estimativa no tamanho do compressor. Entre em contato conosco na TecHelp@EXAIR.com ou ligue para 1-800-903-9247 entre as 8:00 da manhã e as 5:00 da tarde, EST / EDT. Luiz, Thank you for the inquiry. I would like to discuss the application with you further before giving the estimation on the compressor size. Please contact us at TecHelp@EXAIR.com or call 1-800-903-9247 between 8:00 AM and 5:00 PM EST/EDT.

  • @madhanselvaraj7206
    @madhanselvaraj7206 7 років тому

    we would like to take the dealer ship in around chennai please send india dealer contact .

  • @paulmcnamara4332
    @paulmcnamara4332 7 років тому

    Holes are far too big, most air would leave the first slit...

    • @exaircorporation
      @exaircorporation 7 років тому

      Paul, thanks for the comment. That is a good eye and observation. Per our installation and Maintenance Guide we recommend to drill a minimum of six separate 1/8" diameter holes in the tubing in order to eliminate excessive back pressure. If you do not have a drill handy you can use cutters in order to notch the tubing. One benefit to the holes not being installed by us here at the factory is you can choose how the cold air is distributed within your cabinet. If there is a larger heat generating device then you may want to put a larger hole, like the video shows, near that item. I can assure you that we do still get air flow out of the last hole but it is not evenly distributed within our cabinet in order to simulate the uneven heat load throughout the panel. If you would like to discuss the Cold Air Distribution Kits further, please feel free to contact an Application Engineer at 1-800-903-9247.

  • @brianekabuana973
    @brianekabuana973 7 років тому

    Hi. I got a question. How do those air amplifiers work silently at suction process ? Tell me, bro. Thanks hopefully u feed me back soon.

    • @exaircorporation
      @exaircorporation 7 років тому

      @Brian Sullivan, the Air Amplifiers are still going to have sound even on the suction side. You will just be further away from the discharge air which is where the majority of the sound generation comes from. If you would like to discuss this further, please contact an Application Engineer at 1-800-903-9247. Have a great day!

  • @samuelmdouglas
    @samuelmdouglas 7 років тому

    could this used to fill and empty a water tank im my 4wd. i have an onboard commpressor system

    • @exaircorporation
      @exaircorporation 7 років тому

      @Samuelmdouglas, Sorry for the delay in our response. The compressor system on your 4WD is probably going to be a little undersized to operate a Reversible Drum Vac. The RDV consumes 19 SCFM @ 80 psig of inlet pressure. Also, it would need to be used on a steel drum or tank. If you would like to discuss further, please call or e mail. 1-800-903-9247 or Techelp@EXAIR.com Thanks for the question and try to stay shiny side up in the 4WD.

  • @jasonvernon1046
    @jasonvernon1046 7 років тому

    I'm about to do an air audit at a job site, so what is the advantages of this over a bunch of Dawn dish soap and water? I see this as pointless and a complete waste of the customers money and time, so please sell me. Thank You!

    • @exaircorporation
      @exaircorporation 7 років тому

      Jason, Thanks for the comment. The main benefit of utilizing an Ultrasonic Leak Detector over a soap and water mixture is the ability to conduct the leak assessment without contacting the pipes. This means you are not introducing any moisture or chemicals to the piping system which can cause corrosion on piping. There is also the scenario where you may not be able to see all the way around the pipe in order to check for bubbles from a leak. This is where the tube attachment will be able to bend and reach into those places where you can't see to help find hard to reach leaks. The Ultrasonic Leak Detectors can also be used at a distance. Not every fitting or joint has to be checked 360° with a tube attachment. The parabolic dish will permit you to quickly scan the piping and areas of joints or fittings to find the leaks. This will save time when conducting a complete system inspection where you would have to spray down each joint, fitting, and even pipe for that matter. If you would like to discuss the ULD further, or would like to get one into your own hands and give it a test, please contact an Application Engineer at 1-800-903-9247 or Techelp@EXAIR.com . We do honor a 30 day guarantee on stock products that ship within the US. (See our site for more details. www.EXAIR.com)

  • @subhashkumargupta1981
    @subhashkumargupta1981 7 років тому

    Does it work for detection of hydraulic leakage? Secondly suppose if there is flow through nozzle and in the same vicinity there is a leakage as well, will it detect the leakage in that area?

    • @exaircorporation
      @exaircorporation 7 років тому

      Thank you for the excellent question. It has been used by rebuilders of hydraulic cylinders when they are testing the freshly rebuilt cylinder with compressed air before filling it with hydraulic oil. On a hydraulic system you would generally see the fluid at the point of the leak. It may help to find the leak in a dirty system as long as you can get close to the hose and fittings. If there was a pneumatic nozzle that had a lead on the air inlet, you could use the isolating tube attachment to separate the two sounds and determine if the leak is on the air inlet or if the noise is from the nozzle discharge.

  • @biotermicabiotermica4320
    @biotermicabiotermica4320 7 років тому

    Sorry, my name is Sandro. Thanks

  • @biotermicabiotermica4320
    @biotermicabiotermica4320 7 років тому

    Hy, Neil how works whith pipes from heat floor hydronic system.

    • @exaircorporation
      @exaircorporation 7 років тому

      Hell Sandro! If you wanted to use the Ultrasonic Leak Detector to scan the system before it was encased in concrete or other material then it would have a good chance. Once it is encased in in the floor the ULD will not be able to sense the ultrasonic sound. If you would like to discuss further, please let us know at Techelp@EXAIR.com Thanks for the question!

  • @malakanagoudabiradar6858
    @malakanagoudabiradar6858 7 років тому

    By this leak detector,can I detect leak in isolating cock (pneumatic)

    • @exaircorporation
      @exaircorporation 7 років тому

      As long as there is pressure on the valve from the compressed air then the Ultrasonic Leak Detector should help find if there is a leak or not. When going around valves and fittings it is best to use the tube adaptor in order to isolate the noise to a smaller area.

    • @malakanagoudabiradar6858
      @malakanagoudabiradar6858 7 років тому

      Send product details

    • @exaircorporation
      @exaircorporation 7 років тому

      Please let us know an e mail or phone number to reach you at. You can send it to Techelp@EXAIR.com

  • @millwrightlee9656
    @millwrightlee9656 7 років тому

    good thing compressed air is cheap. lol

    • @exaircorporation
      @exaircorporation 7 років тому

      Sadly enough there are employees in the workforce that believe compressed air actually is cheap. Here at EXAIR, we know that is not the case. The current average in the MidWest for compressed air is $0.25 / 1,000 Standard Cubic Feet of compressed air. This ranks compressed air as one of the more costly utilities companies utilize and that is why EXAIR is dedicated to developing and offering Intelligent Compressed Air Products® that help optimize your compressed air usage. The Vac-U-Gun product does utilize compressed air which enables us to have no internal moving parts, no motors, bearing, or impellers to wear out, as well as simplistic installation and use. There are certain areas / environments where compressed air may be the only utility available for use and that is where the Vac-U-Gun can help decrease cleaning times as well as be an efficient option for compressed air utilization. If you would like to see how we suggest optimizing compressed air use within your facility, please follow the link to our 6 Steps to Compressed Air Optimization, ow.ly/n8sj305RgIl. Thanks for the comment and please feel free to reach out if you have any other questions!

  • @dheerajnair-vlogsreviewsmo9845
    @dheerajnair-vlogsreviewsmo9845 7 років тому

    Is it necessary to give inlet of air to the air receiver tank from the bottom of the tank and let the outlet from top in a vertical tank???

    • @exaircorporation
      @exaircorporation 7 років тому

      You do not need to plumb the inlet into the bottom of the tank in this scenario. We would generally recommend to bring the compressed air into the lower ports on the side and not he actual bottom of the tank. The bottom port should always have a condensate drain located on the port. If your application requires the compressed air inlet to come in on a higher side port you could use one of the other side ports for the exhaust air, it is simply better practice to use a higher port for the outbound air. If you have any other questions or would like to discuss further, please contact an Application Engineer at 1-800-903-9247.

  • @user-xu8ug9wp8b
    @user-xu8ug9wp8b 8 років тому

    can you make it filter the waste cement paste water when we wash off by water jet after installation of fresh concrete on the sub concrete and laste spray surface retarder. We need vacuuming machine and filter paste water simaltaneously. CEMENT PASTE WITH RUNNING WATER BY WATER JET WASHING OUT AFTER THE EXPOSED AGGREGATE CONCRETE FINISH. Please, advised with me and inform your professional idea bout my situation. Awaiting reply.

    • @exaircorporation
      @exaircorporation 8 років тому

      This has not been tested on the Chip Trapper systems. As long as the system is flushed and cleaned quickly and the residual concrete is not allowed to set up inside of the valve or filter bag it should filter the solids just fine. The vacuum will not suck up only dust. The solids would need to be suspended in the water and vacuumed up from there. If you would like to discuss further, please feel free to contact us at 1-800-903-9247. Thank you for the question!

  • @karenyanez9814
    @karenyanez9814 8 років тому

    Hi, I need your help. I need a nozzle to atomize a mix diesel/air to combust by 20 minutes with a 2mL/min flow (fuel) and air at different flow. Can you help me?

  • @mustafaevrenpolat
    @mustafaevrenpolat 8 років тому

    lowest volt ?

  • @stevenmartens4389
    @stevenmartens4389 8 років тому

    hey just want to find out if this device can detect a vacuum leak and if it can how to do so thanks

    • @exaircorporation
      @exaircorporation 8 років тому

      Steven,The Ultrasonic Leak Detector can be used to detect vacuum leaks. The process is the same as when testing for a pressure leak. If there is a leak then it is going to still give an ultrasonic sound due to the air passing through an orifice. If you would like to discuss this further, please contact an Application Engineer at 1-800-903-9247.

  • @ronnichols9510
    @ronnichols9510 8 років тому

    will this pump transfer used motor oil from one drum to another , I tried and it only moved about 1/3 of barrel then stopped ..

    • @exaircorporation
      @exaircorporation 8 років тому

      +Ron Nichols, The Reversible Drum Vac should handle most motor oils just fine. For thicker heavier weights we do offer a High Lift Reversible Drum Vac. There are several other variables that go into whether the Reversible Drum Vac will operate properly. Please contact us at 1-800-903-9247 and ask for an Application Engineer, we would greatly appreciate the opportunity to trouble shoot this application with you. We look forward to your call!

  • @Quick76ers
    @Quick76ers 8 років тому

    can this vacuum be use to help your water go uphill or up to mountain top?

  • @victorrafaelpereiralameda8370
    @victorrafaelpereiralameda8370 8 років тому

    is it possible to detect a bearing failure?

    • @exaircorporation
      @exaircorporation 8 років тому

      Victor, Sorry for the delay in our response. The Ultrasonic Lead Detector can actually be used to listen for mechanical vibrations that lead to bearing failures. For this application we would generally use the tube attachment and pinpoint the bearings in question. If you would like to discuss this further, please contact an Application Engineer at 1-800-903-9247.

    • @jasonvernon1046
      @jasonvernon1046 7 років тому

      You need an SPM meter or a vibration meter with historic analysis, meaning in order to detect a failure you need a graph over the life of the bearing.

    • @exaircorporation
      @exaircorporation 7 років тому

      This could also be achieved with the ULD if you were to take baseline measurements when the product was new. While the ULD is not built specifically for bearing maintenance, it is similar to a mechanical stethoscope where you will be able to hear chattering and the vibrations that can generally be isolated to the bearing housings on the part.

    • @victorrafaelpereiralameda8370
      @victorrafaelpereiralameda8370 7 років тому

      OK OK Many thanx!!!

  • @exaircorporation
    @exaircorporation 9 років тому

    @iso plastic, The Reversible Drum Vac product line is not recommended for use with any material which has a low flash point or with flammable liquids such as fuel oil, alcohol, mineral spirits, gasoline, or kerosene. If you would like to discuss this further, feel free to contact an Application Engineer at 1-800-903-9247. Thanks for the question and have a great day!

  • @isoplastik5297
    @isoplastik5297 9 років тому

    Hi sir Is that can working with solvent like isobutanol

  • @carpetsparklecarpetcleanin1874
    @carpetsparklecarpetcleanin1874 9 років тому

    Very cool.

  • @joyfilters
    @joyfilters 9 років тому

    Are these standard 1 1/2" vacuum hose?

    • @exaircorporation
      @exaircorporation 9 років тому

      @JoyFilters, The Reversible Drum Vac family all operate off a 1 1/2" I.D. vacuum / discharge hose. This pushes on to a barbed fitting which is part of the quick disconnect. If you would like more information, feel free to contact us at 1-800-903-9247.

  • @joyfilters
    @joyfilters 9 років тому

    What size compressed air line are you using? How much air pressure and or CFM does this unit require?

    • @exaircorporation
      @exaircorporation 9 років тому

      @JoyFilters, For this video we were utilizing a 3/8" I.D. compressed air hose. The operating pressure for the Reversible Drum Vac is 80 psig inlet pressure. When operating at 80 psig the unit will utilize 19 SCFM to fill and or empty the drum. If you would like to know more, feel free to call an Application Engineer at 1-800-903-9247. Thanks for the questions!

  • @leandrodelagarza2962
    @leandrodelagarza2962 9 років тому

    2 questions: 1.-What is level noise produced by cooler system in db? 2.-What happen if humidity separator fails, there will be a water iside cabinet that can be damage the electronics parts?

    • @exaircorporation
      @exaircorporation 9 років тому

      Leandro, Thank you for the inquiry on our Cabinet Cooler Systems. To answer your questions: 1. The noise level produced by our Cabinet Cooler Systems will vary depending on the NEMA type and cooling capacity of the system. The range of noise levels is from 59 to 85 dBA form 3 feet away. These all fall within the allowable noise level exposure guidelines from OSHA. 2. If you have a dryer on the entire compressed air system and it fails, each EXAIR Cabinet Cooler System includes an auto drain filter separator for dirt and water particulate down to 5 micron. We also offer an optional oil removal filter that will then filter the compressed air supply down to 0.03 micron particulate size. If these filters begin to “fail” the general symptom is the filter becomes clogged causing a pressure drop across the filter. Once the pressure drop reaches more than 5 psig we would recommend to replace the filter element. The filter elements are readily available for all of our filter units. If the filter fails catastrophically and no longer removes moisture from the compressed air, then moisture could potentially pass into the Cabinet Cooler System. Fortunately the Cabinet Cooler System outlet has a cold air distribution hose inside of the enclosure which will act as a condensate trap, if you will, to help collect the atomized moisture. If the unit is installed properly then the moisture will have a low possibility of exiting into the enclosures air space. Please let me know if you would like to discuss this further. 1-800-903-9247

    • @leandrodelagarza2962
      @leandrodelagarza2962 9 років тому

      thanks for your answer, we are looking in our company the most efficiently cooler system, i will try to test one like this. and follow their advice. Thanks A lot

    • @exaircorporation
      @exaircorporation 9 років тому

      Leandro De La Garza, Thank you for the questions and the response. I am glad you found our video and information useful. In the future, for a more immediate response, feel free to contact us through e mail at techelp@EXAIR.com or by phone 1-800-903-9247. We will gladly answer any an all questions you have on our products. Thanks again. ~Brian Farno

  • @exaircorporation
    @exaircorporation 9 років тому

    Gary, A high volume low pressure pump is not going to be able to properly supply our Vac U Gun with the pressure that it requires for optimal performance. The EXAIR Vac U Gun is designed to be operated at 80 psig inlet pressure and utilize 13 SCFM of compressed air. The turbine pump you are looking at using is something that I would generally associate with a paint sprayer. Our products are all designed to be used with industrial air compressors, at a minimum of 20 psig inlet pressure. If you would like to discuss further, please do not hesitate to contact us at 1-800-903-9247.

  • @petestone2419
    @petestone2419 9 років тому

    is it possible to detect a leak behind a wall or in airways inside of a block (of plastic for example)

    • @exaircorporation
      @exaircorporation 9 років тому

      Pete, It is possible to use the Ultrasonic Leak Detector to find large leaks that are close to a barrier such as, drywall or plywood. This means you will not be able to determine if there are extremely low flowing leaks, they will need to be more substantial. The best operation for the Ultrasonic Leak Detector will be on exposed pipes. If you would like to discuss this further, please feel free to contact us. 1-800-903-9247